##TITLE= Audit trail, TopSpin 4.4.1
##JCAMPDX= 5.01
##ORIGIN= Bruker BioSpin GmbH & Co. KG
##OWNER= nmrsu
$$ /opt/topspin4.4.1/nmrdata05_09_2025/Ghayoor/KB-P19-(NO2)-V1/3/pdata/1/auditp.txt
##AUDIT TRAIL=  $$ (NUMBER, WHEN, WHO, WHERE, PROCESS, VERSION, WHAT)
(   1,<2025-09-16T10:10:14.725+0500>,<nmrsu>,<localhost.localdomain>,<cprserver>,<TopSpin 4.4.1>,
      <new/edc PROCNO=1>)
(   2,<2025-09-16T10:33:57.808+0500>,<nmrsu>,<localhost.localdomain>,<proc1d>,<TopSpin 4.4.1>,
      <Start of raw data processing
       efp LB = 1 FT_mod = 6 PKNL = 1 PHC0 = -7.515447 PHC1 = -79.51804 SI = 32K
       fid double data hash MD5: 64K
       EA F5 8C D6 F8 47 27 D1 49 32 2E EC CE 8F FF 5A
       data hash MD5: 32K
       23 CE 81 76 41 91 A8 58 4C C0 15 8B 99 28 C4 1F>)
(   3,<2025-09-16T10:34:04.952+0500>,<nmrsu>,<localhost.localdomain>,<proc1d>,<TopSpin 4.4.1>,
      <apk
       data hash MD5: 32K
       75 64 58 FE 1B 66 C9 F2 F0 23 FA 7A 8A 94 46 6C>)
(   4,<2025-09-16T10:34:06.485+0500>,<nmrsu>,<localhost.localdomain>,<proc1d>,<TopSpin 4.4.1>,
      <abs ABSG = 5
       data hash MD5: 32K
       7A CF 41 36 D4 3F F3 7C 0F 5B 20 73 4B E4 C2 9E>)
(   5,<2025-09-16T10:46:57.294+0500>,<nmrsu>,<localhost.localdomain>,<proc1d>,<TopSpin 4.4.1>,
      <Start of raw data processing
       efp LB = 1 FT_mod = 6 PKNL = 1 PHC0 = 32.92521 PHC1 = -156.7933 SI = 32K
       fid double data hash MD5: 64K
       17 3E 36 DF F2 4E FB 41 93 57 D4 BB 77 E7 01 1D
       data hash MD5: 32K
       0C 8A 7D A4 3C 54 19 76 CB 3A 07 AF A0 2C 31 DE>)
(   6,<2025-09-16T11:33:17.693+0500>,<nmrsu>,<localhost.localdomain>,<proc1d>,<TopSpin 4.4.1>,
      <Start of raw data processing
       efp LB = 1 FT_mod = 6 PKNL = 1 PHC0 = 32.92521 PHC1 = -156.7933 SI = 32K
       fid double data hash MD5: 64K
       26 03 77 31 1A 99 64 01 E7 B9 E4 CE F8 A7 98 AB
       data hash MD5: 32K
       85 2C 6C 9D 5A B0 4D F3 A8 19 68 1A 7B DF F8 B6>)
(   7,<2025-09-16T13:32:31.927+0500>,<nmrsu>,<localhost.localdomain>,<proc1d>,<TopSpin 4.4.1>,
      <Start of raw data processing
       efp LB = 1 FT_mod = 6 PKNL = 1 PHC0 = 32.92521 PHC1 = -156.7933 SI = 32K
       fid double data hash MD5: 64K
       17 67 21 04 F3 DB 6D 10 DD 95 F6 69 6A A1 D2 FA
       data hash MD5: 32K
       51 8C FE D6 35 23 36 43 24 B1 76 86 50 89 76 E1>)
(   8,<2025-09-16T13:35:50.973+0500>,<nmrsu>,<localhost.localdomain>,<dataserver>,<TopSpin 4.4.1>,
      <Start of interactive peak picking
       data hash MD5: 32K
       51 8C FE D6 35 23 36 43 24 B1 76 86 50 89 76 E1>)
(   9,<2025-09-16T13:35:56.930+0500>,<nmrsu>,<localhost.localdomain>,<peak>,<TopSpin 4.4.1>,
      <1D Peak picking
       data hash MD5: 32K
       51 8C FE D6 35 23 36 43 24 B1 76 86 50 89 76 E1>)
(  10,<2025-09-16T13:36:05.225+0500>,<nmrsu>,<localhost.localdomain>,<dataserver>,<TopSpin 4.4.1>,
      <End of interactive peak picking
       data hash MD5: 32K
       51 8C FE D6 35 23 36 43 24 B1 76 86 50 89 76 E1>)
(  11,<2025-09-16T13:36:28.376+0500>,<nmrsu>,<localhost.localdomain>,<proc1d>,<TopSpin 4.4.1>,
      <Start of raw data processing
       efp LB = 1 FT_mod = 6 PKNL = 1 PHC0 = 32.92521 PHC1 = -156.7933 SI = 32K
       fid double data hash MD5: 64K
       17 67 21 04 F3 DB 6D 10 DD 95 F6 69 6A A1 D2 FA
       data hash MD5: 32K
       51 8C FE D6 35 23 36 43 24 B1 76 86 50 89 76 E1>)
(  12,<2025-09-16T13:36:46.382+0500>,<nmrsu>,<localhost.localdomain>,<cprserver>,<TopSpin 4.4.1>,
      <changed parameter F1 LB to 5.00>)
(  13,<2025-09-16T13:36:49.978+0500>,<nmrsu>,<localhost.localdomain>,<proc1d>,<TopSpin 4.4.1>,
      <Start of raw data processing
       efp LB = 5 FT_mod = 6 PKNL = 1 PHC0 = 32.92521 PHC1 = -156.7933 SI = 32K
       fid double data hash MD5: 64K
       17 67 21 04 F3 DB 6D 10 DD 95 F6 69 6A A1 D2 FA
       data hash MD5: 32K
       74 0F 63 AA E3 5B 48 7D B0 0C 32 63 B3 26 60 5A>)
(  14,<2025-09-16T13:37:05.346+0500>,<nmrsu>,<localhost.localdomain>,<cprserver>,<TopSpin 4.4.1>,
      <changed parameter F1 LB to 3.00>)
(  15,<2025-09-16T13:37:06.197+0500>,<nmrsu>,<localhost.localdomain>,<proc1d>,<TopSpin 4.4.1>,
      <Start of raw data processing
       efp LB = 3 FT_mod = 6 PKNL = 1 PHC0 = 32.92521 PHC1 = -156.7933 SI = 32K
       fid double data hash MD5: 64K
       17 67 21 04 F3 DB 6D 10 DD 95 F6 69 6A A1 D2 FA
       data hash MD5: 32K
       13 F2 B9 6A 68 C2 BD C4 31 66 2F 78 42 13 05 5B>)
(  16,<2025-09-16T13:37:09.366+0500>,<nmrsu>,<localhost.localdomain>,<cprserver>,<TopSpin 4.4.1>,
      <changed parameter F1 LB to 1.00>)
(  17,<2025-09-16T13:37:10.239+0500>,<nmrsu>,<localhost.localdomain>,<proc1d>,<TopSpin 4.4.1>,
      <Start of raw data processing
       efp LB = 1 FT_mod = 6 PKNL = 1 PHC0 = 32.92521 PHC1 = -156.7933 SI = 32K
       fid double data hash MD5: 64K
       17 67 21 04 F3 DB 6D 10 DD 95 F6 69 6A A1 D2 FA
       data hash MD5: 32K
       51 8C FE D6 35 23 36 43 24 B1 76 86 50 89 76 E1>)
(  18,<2025-09-16T14:47:42.677+0500>,<nmrsu>,<localhost.localdomain>,<proc1d>,<TopSpin 4.4.1>,
      <Start of raw data processing
       efp LB = 1 FT_mod = 6 PKNL = 1 PHC0 = 32.92521 PHC1 = -156.7933 SI = 32K
       fid double data hash MD5: 64K
       9E AC 31 9E 13 A2 B9 22 E4 35 3F 3A C8 E8 62 5A
       data hash MD5: 32K
       57 76 EC B0 89 81 D6 37 97 D1 B1 54 3A 18 69 06>)
(  19,<2025-09-16T15:43:24.610+0500>,<nmrsu>,<localhost.localdomain>,<dataserver>,<TopSpin 4.4.1>,
      <Start of interactive peak picking
       data hash MD5: 32K
       57 76 EC B0 89 81 D6 37 97 D1 B1 54 3A 18 69 06>)
(  20,<2025-09-16T15:43:29.433+0500>,<nmrsu>,<localhost.localdomain>,<peak>,<TopSpin 4.4.1>,
      <1D Peak picking
       data hash MD5: 32K
       57 76 EC B0 89 81 D6 37 97 D1 B1 54 3A 18 69 06>)
(  21,<2025-09-16T15:43:32.068+0500>,<nmrsu>,<localhost.localdomain>,<peak>,<TopSpin 4.4.1>,
      <1D Peak picking
       data hash MD5: 32K
       57 76 EC B0 89 81 D6 37 97 D1 B1 54 3A 18 69 06>)
(  22,<2025-09-16T15:43:43.895+0500>,<nmrsu>,<localhost.localdomain>,<peak>,<TopSpin 4.4.1>,
      <1D Peak picking
       data hash MD5: 32K
       57 76 EC B0 89 81 D6 37 97 D1 B1 54 3A 18 69 06>)
(  23,<2025-09-16T15:43:45.146+0500>,<nmrsu>,<localhost.localdomain>,<peak>,<TopSpin 4.4.1>,
      <1D Peak picking
       data hash MD5: 32K
       57 76 EC B0 89 81 D6 37 97 D1 B1 54 3A 18 69 06>)
(  24,<2025-09-16T15:43:46.860+0500>,<nmrsu>,<localhost.localdomain>,<peak>,<TopSpin 4.4.1>,
      <1D Peak picking
       data hash MD5: 32K
       57 76 EC B0 89 81 D6 37 97 D1 B1 54 3A 18 69 06>)
(  25,<2025-09-16T15:43:50.864+0500>,<nmrsu>,<localhost.localdomain>,<peak>,<TopSpin 4.4.1>,
      <1D Peak picking
       data hash MD5: 32K
       57 76 EC B0 89 81 D6 37 97 D1 B1 54 3A 18 69 06>)
(  26,<2025-09-16T15:43:56.138+0500>,<nmrsu>,<localhost.localdomain>,<peak>,<TopSpin 4.4.1>,
      <1D Peak picking
       data hash MD5: 32K
       57 76 EC B0 89 81 D6 37 97 D1 B1 54 3A 18 69 06>)
(  27,<2025-09-16T15:43:59.272+0500>,<nmrsu>,<localhost.localdomain>,<peak>,<TopSpin 4.4.1>,
      <1D Peak picking
       data hash MD5: 32K
       57 76 EC B0 89 81 D6 37 97 D1 B1 54 3A 18 69 06>)
(  28,<2025-09-16T15:44:00.691+0500>,<nmrsu>,<localhost.localdomain>,<peak>,<TopSpin 4.4.1>,
      <1D Peak picking
       data hash MD5: 32K
       57 76 EC B0 89 81 D6 37 97 D1 B1 54 3A 18 69 06>)
(  29,<2025-09-16T15:44:02.308+0500>,<nmrsu>,<localhost.localdomain>,<peak>,<TopSpin 4.4.1>,
      <1D Peak picking
       data hash MD5: 32K
       57 76 EC B0 89 81 D6 37 97 D1 B1 54 3A 18 69 06>)
(  30,<2025-09-16T15:44:06.328+0500>,<nmrsu>,<localhost.localdomain>,<peak>,<TopSpin 4.4.1>,
      <1D Peak picking
       data hash MD5: 32K
       57 76 EC B0 89 81 D6 37 97 D1 B1 54 3A 18 69 06>)
(  31,<2025-09-16T15:44:10.349+0500>,<nmrsu>,<localhost.localdomain>,<peak>,<TopSpin 4.4.1>,
      <1D Peak picking
       data hash MD5: 32K
       57 76 EC B0 89 81 D6 37 97 D1 B1 54 3A 18 69 06>)
(  32,<2025-09-16T15:44:15.936+0500>,<nmrsu>,<localhost.localdomain>,<dataserver>,<TopSpin 4.4.1>,
      <End of interactive peak picking
       data hash MD5: 32K
       57 76 EC B0 89 81 D6 37 97 D1 B1 54 3A 18 69 06>)
(  33,<2025-09-16T15:59:59.837+0500>,<nmrsu>,<localhost.localdomain>,<proc1d>,<TopSpin 4.4.1>,
      <Start of raw data processing
       efp LB = 1 FT_mod = 6 PKNL = 1 PHC0 = 32.92521 PHC1 = -156.7933 SI = 32K
       fid double data hash MD5: 64K
       F4 90 28 4B D8 08 47 70 F4 25 5B E9 25 73 A9 0E
       data hash MD5: 32K
       99 9E 42 B0 74 63 73 B0 E5 3C F6 36 CC 40 A2 04>)
(  34,<2025-09-27T12:39:31.386+0500>,<nmrsu>,<localhost.localdomain>,<cprserver>,<TopSpin 4.4.1>,
      <changed parameter F1 SR to 69.22>)
##END=

$$ hash MD5
$$ 69 F4 9D 06 83 37 ED 11 91 C1 D7 85 33 BE 17 28